Optimal discharging conditions for battery storage systems

2018 
Abstract The paper presents the practical results of measuring different types of lithium iron phosphate (LiFePO 4 ) and lithium titanate (LTO) batteries during the loading by charging/discharging cycles, with particular emphasis on cell heating and thermal capacity of the entire system. Finally, it presents recommendations on the operating conditions of LiFePO 4 cells and batteries.