Inter-laboratory analysis of endotoxin in cotton dust samples.

2004 
Background Currently there are no mandated exposure limits for endotoxin, but recommended limits have been proposed and interest expressed in developing quantitative standards for endotoxin. A limitation for developing a quantitative standard for endotoxin is the measurement variability between laboratories. Inter-laboratory variability of up to four orders of magnitude has been reported for replicate samples. To evaluate both the intra- and inter-laboratory variability, Round-Robin studies were conducted using replicate samples of cotton dust. Methods Replicate samples of cotton dust were collected using vertical elutriators (VE) in a model cardroom. Each participating laboratory evaluated the samples for endotoxin using: their normal extraction procedure; a common extraction procedure; and a common extraction procedure and the same type and lot of a commercially available endotoxin kit. Results These studies demonstrated that both intra- and inter-laboratory variability is reduced by using a common extraction protocol and a common assay kit; however, significant differences remained between the laboratories. Conclusions The data suggest that intra-laboratory assays can be used to assess the relative differences between endotoxin samples, however, the inter-laboratory variability suggests that limitations remain for developing a reliable exposure assessment assay that could be used for a quantitative exposure standard.