Radon Kinetics in a Basement Space Measured with Different Devices.

2021 
ABSTRACT Although indoor monitoring of radon and benchmarking of radon measurement devices remain important research topics, few intercomparisons of active radon measurement devices have been performed under realistic conditions, let alone dynamic ones enabling comparison of their transient behavior. Five different radon monitors were therefore placed in a poorly ventilated basement space under three different conditions: 24 h under a steady, elevated radon level, 24 h with fans turned on to produce a radon washout transient, and 9 d with fans turned off for a radon buildup transient. Resulting radon concentrations varied between ~200 and ~2,000 Bq m-3. Accuracy of the devices were evaluated using root-mean-square error, and ventilation data were fit to first order linear compartmental models. To more accurately model behaviors such as cyclic diurnal variations, the source term corresponding to entry of radon from soil into the basement was considered to be non-constant, as it is likely to vary drastically with both the indoor-outdoor pressure differential and soil concentration variations. The improved radon washout model fit very well with the measurements. Despite a wide variety in list prices, all devices performed similarly during transients and at different radon concentrations.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    16
    References
    0
    Citations
    NaN
    KQI
    []