Seismic Performance Evaluation of Reinforced Concrete Moment Framed Low-story School buildings
2013
Abstract Many school buildings are not applied seismic code because of small size structures. But it must be designed to show enough structural performance when subject to earthquake due to the fact that most of school buildings are generally used as public shelters when the natural disasters. In this study, the seismic risk of the reinforced concrete school building structure which is the most common types of school structures was evaluated by using the seismic performance evaluation methods. As a result, model structures don't have enough seismic performance. Key Words : School buildings, Seismic design, Seismic performance evaluation, Moment frame 본 논문은 국토해양부 첨단도시개발사업의 연구비지원(’09 첨단도시A01)으로 수행되었음. * Corresponding Author : Ju-Yeon Han(Dankook Univ.) Tel: +82-31-8005-2641 email: hanzzu@dankook.ac.kr Received August 2, 2013 Revised (1st August 21, 2013, 2nd September 5, 2013) Accepted September 6, 2013 1. 서론 2010년 아이티 및 페루에서 발생한 지진은 내진설계의 중요성을 시사하고 있다. 내진설계가 전혀 이루어지지 않은 아이티에서의 지진은 막대한 인명 및 재산피해가 발생한 반면, 건축물 및 사회기간시설물에 내진설계가 어느 정도 적용된 칠레에서는 지진의 규모가 8.0[1]으로 아이티의 7.0에 비해 컸으나 그 피해 규모는 매우 작은 것으로 보고되었기 때문이다. 특히, 중국의 스촨성 지진 시 약 7,000여개의 학교가 피해를 입었으며 1,900명 이상의 학생이 매몰된 것으로 보도된 바 있어 학교건물의 내진성능에 대한 필요성이 강하게 제기되었다.한편 국내의 대부분의 학교 건물은 내진설계기준이 적용되기 이전인 1988년 이전에 설계되었으며[2], 이후에 지어진 학교의 경우도 내진설계 적용대상에서 제외된 5층 이하의 건물로서 내진설계의 적용기준에 미흡하여 내진성능이 없을 것으로 판단된다[3].이와 관련하여 현재까지 국내 학교 건물의 내진성능 평가 및 보강에 대한 많은 연구가 진행 중에 있다. 박태원(2009)등은 상세재해지도를 고려하여 학교건축물의 내