Energetic and Exergetic Analysis of Bagasse & coal fired Boiler use in Textile Process Plant
2016
in this study, energetic and exergetic analysis of steam generation device which is use in 25 MW capacities Textile Process and also in captive power plants. To analyze the boiler detailed in energetic and exergetic losses has been presented. Due to economically and reduce environmental pollution by mixing of fuel is best for steam generation plant. Energy analysis give only quantities result while energy analysis presents qualitative result about actual energy consumption. Exergy is maximum theoretical useful work at dead state that may be received from energy in a system of ideal machines. Take all data from T. M. Patel Dying Industries PVT. LTD., Kadodra - Surat. So here, energetic & exergetic analysis, exergetic destruction by mixing of bagasse and coal used in boiler to analyze energetic and exergetic analysis done and select best for (40% B+ 60% L) used to produce economical for steam generation. Keywords— Boiler Plant, Fuel and its combustion, Energetic & Exergetic analysis, Efficiency calculation, exergetic destruction.