$Q$ Spectroscopy With Superconducting Sensor Microcalorimeters

2013 
The total reaction energy ( Q ) of individual nuclear decays was measured using microcalorimeters with transition-edge-sensor (TES) thermometers. For alpha-decaying actinides (e.g., U-235, Pu-239, Np-237, Am-241), Q is in the 4-6 MeV range. Nearly all of this energy goes into the relatively light alpha particle, and approximately 100 keV is left over for the much heavier, recoiling daughter atom. Alpha-particle energy spectroscopy with TES-microcalorimeters has shown the ability to simultaneously resolve peaks that overlap in conventional alpha spectroscopy, with resolution now less than 1 keV full-width-at-half-maximum (FWHM) at 5.3 MeV. For total reaction energy spectroscopy, we use the same TES design as our alpha detectors, but embed a small radioactive sample (of about 1 Bq) directly inside an absorber designed to capture all the emitted particles (alpha, recoil nucleus, electrons, X-rays) with near 100% efficiency. We have measured Q -spectra of alpha-decaying isotopes with spectral resolution of 2-3 keV FWHM. For some actinide analytical problems, the Q -spectrum is simpler than the alpha-spectrum: fewer peaks, further apart, and easier to quantify. We will discuss sensor design, methods for embedding radionuclides, and spectral data.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    13
    Citations
    NaN
    KQI
    []