Index of convexity: A novel method for assessing liver functional reserve using technetium-99m-galactosyl human serum albumin liver scintigraphy

2017 
: Preoperative evaluation of liver functional reserve is important in hepatobiliary surgery. Although the indocyanine green retention rate at 15 minutes (ICG-R15) is the gold standard for this purpose, a new method without technical complexity would be preferable. We assessed the usefulness of the previously established index of convexity (IOC). In total, 159 consecutive patients who underwent both technetium-99m-galactosyl human serum albumin (99mTc-GSA) scintigraphy and the ICG-R15 were included. Correlation coefficients between indices from 99mTc-GSA scintigraphy and blood examinations including ICG-R15 were evaluated, and a conversion formula from the IOC to the ICG-R15 was established. The IOC was calculated as [L(15) × 2 - L(3) - L(27)] / [L(27) - L(3)], where L(t) indicates the radiation counts within the whole liver at t minutes after 99mTc-GSA injection. The IOC showed a significantly stronger correlation with the ICG-R15 (r = -0.532, p < 0.001) than the index of blood clearance (HH15) and the receptor index (LHL15). A formula for estimating ICG-R15 from IOC was "ICG-R15 = -31.0 × IOC + 30.1". In conclusion, the IOC is a better index for evaluating preoperative liver functional reserve than the conventional indices. A formula for estimating ICG-R15 from the IOC will be useful.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    27
    References
    1
    Citations
    NaN
    KQI
    []