[Removal of AOX and Chroma in Biologically Treated Effluent of Chemical Dyestuff Wastewater with Nanoscale Ni/Fe].

2016 
Nanoscale Ni/Fe was applied to biologically treated effluent of chemical dyestuff wastewater. The removal rates of absorbable organic halogens (AOX) and chroma were investigated at different Ni loadings (0-5%), initial wastewater pH (4.1-10.0), Ni/Fe dosage (1-5 g x L(-1)) and reaction time (0.5-96 h). The results showed that the removal rates of AOX and chroma firstly increased and then decreased with the increase of the Ni loading, while continuously increased with the decrease of the initial wastewater pH and the increase of Ni/Fe dosage. The optimal condition was Ni loading of 1%, initial wastewater pH of 4.1 and Ni/Fe dosage of 3 g x L(-1), under which 29.2% of AOX and 79.6% of chroma were removed after 24 h reaction, and 50.6% of AOX and 80.7% of chroma were removed after 96 h reaction. GC-MS analysis revealed that toxicants such as chlorinated anilines, p-nitroaniline, 4-methoxy-2-nitroaniline and halogenated hydrocarbons were efficiently removed.