Comparison of PEC approaches for SCALPEL

2000 
SCALPEL is a projection electron lithography technology with resolution limited by aberrations and electron-electron interactions, not diffraction. The main CD control issue is adequate dose latitude, for image blur approaching the feature size in a high throughput scenario. This includes the effect of the unwanted electron back-scatter (EBS) proximity dose. Due to operation at 100KeV, the back-scatter range is large (~ 25 microns) and resulting CD changes depend only on the density surroundings of a critical feature. We compare mask pattern data biasing (adjustment of binary mask object sizes) with our proposed GHOST scheme; both available as methods of proximity effect correction (PEC). We demonstrate data bias for a gate-level test pattern with realistic features and density, using a very simple model. These CD control results are confirmed with CAPROX(TM), a complete device-pattern PEC calculation tool from Sigma-C.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    1
    Citations
    NaN