Consistency of strength curves for determining maximal effort production during isokinetic knee testing of anterior cruciate ligament-deficient patients.
2016
ABSTRACTThe purpose of this investigation was to attempt to establish decision rules for determining maximal effort production during isokinetic strength testing of unilateral anterior cruciate ligament-deficient patients based on the degree of strength curve consistency within a set. Thirty-three participants performed six bilateral knee extension and flexion exertions at maximal effort and at 80% of perceived maximum at testing velocities of 60 and 180°s–1. Within-set consistency was quantified by computation of the variance ratio across strength curves. Tolerance interval-based cutoff scores covering 99% of the population were calculated for declaring efforts as being maximal or not at confidence levels of 90%, 95%, and 99%. The sensitivity percentages attained for the injured knee for both testing velocities ranged between 9.1% and 27.2%, while specificity percentages ranged between 84.8% and 100%. For the non-injured knee, sensitivity values for both testing velocities ranged between 21.2% and 45.0%,...