MASS SPECTROMETRIC MEASUREMENTS ON INDUCTIVELY COUPLED FLUOROCARBON PLASMAS : POSITIVE IONS, RADICALS AND ENDPOINT DETECTION

1999 
Positive ions and radicals in C2F6 and CHF3 high density discharges were measured using a direct-line-of-sight mass spectrometer. The ion energy distributions of the dominant ions were measured as a function of process conditions. Appearance potential mass spectrometry was performed to measure trends of the radical densities. For C2F6 plasmas CF3 and CF3+are the most abundant neutral and ionic species, respectively. CF3 is the most abundant neutral species for a CHF3 plasma, whereas CHF2+ and CF+ are the most abundant ionic species at 600–1000 and 1400 W, respectively. Erosion of the quartz coupling window is an important contaminant source for our inductively coupled plasma system. For comparison, downstream mass spectrometry was also applied using a closed ion source system since this approach is of interest for real-time monitoring and control. Endpoint detection for Si and SiO2 film etching in a CHF3 plasma was investigated using the downstream mass spectrometer system and compared with data obtained ...