RADON IN HOMES FOLLOWING ITS REDUCTION IN A COMMUNITY WATER SUPPLY

1991 
Radon in home air and domestic water supplies was measured throughout a rural community before and after the installation of a diffused aeration system that reduced water radon at the source from approximately 20,000 to <1,000 pCi/L. Continuous monitoring of air radon indicated short-term contributions from water use in some homes