Integrating Smart Ceiling Fans and Communicating Thermostats to Provide Energy-Efficient Comfort

2020 
Author(s): Raftery, Paul; Miller, Dana; Zhang, Hui; Peffer, Therese; Brager, Gail; Graham, Lindsay T; Present, Elaina; Arens, Edward; Douglas-Jaimes, David; Paliaga, Gwelen; Brooks, Andy; Cohn, Sebastian; Greene, Mitch | Abstract: The project goal was to identify and test the integration of smart ceiling fans and communicating thermostats. These highly efficient ceiling fans use as much power as an LED light bulb and have onboard temperature and occupancy sensors for automatic operationbased on space conditions. The Center for the Environment (CBE) at UC Berkeley led the research team including TRC, Association for Energy Affordability (AEA), and Big Ass Fans (BAF). The research team conducted laboratory tests, installed99 ceiling fans and 12 thermostats in four affordable multifamily housing sites in California’s Central Valley, interviewed stakeholders to develop a case study, developed an online design tool and design guide, outlined codes and standards outreach, and published several papers.The project team raised indoor cooling temperature setpoints and used ceiling fans as the first stage of cooling; this sequencing of ceiling fans and air conditioningreducesenergy consumption, especially during peak periods, while providing thermal comfort.The field demonstration resulted in 39% measured compressor energy savings during the April–October cooling seasoncompared to baseline conditions, normalized for floor area. Weather-normalized energy use varied from a 36% increase to 71% savings, withmedian savings of 15%.This variability reflects the diversity in buildings, mechanical systems, prior operation settings, space types, andoccupants’ schedules,preferences, and motivations. All commercial spaces with regular occupancy schedules (and twoof the irregularly-occupied commercial spaces and one of the homes) showed energy savings on an absolute basis before normalizing for warmer intervention temperatures,and 10 of 13 sites showed energy savings on a weather-normalized basis. The ceiling fans provided cooling for one site for months during hot weather when the coolingequipment failed.Occupants reported high satisfaction with the ceiling fans and improved thermal comfort. This technology can apply to new and retrofit residential and commercial buildings.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    2
    Citations
    NaN
    KQI
    []