Benchmark problem for response control of wind-excited tall buildings

2004 
This paper presents an overview and problem definition of a benchmark problem for the response control of wind-excited tall buildings. The building considered is a 76-story 306 m concrete office tower proposed for the city of Melbourne, Australia. The building is slender with a height to width ratio of 7.3; hence, it is wind sensitive. Wind tunnel tests for such a 76-story building model have been conducted at the University of Sydney and the results of across-wind data are used in the present benchmark problem. Either active, semiactive, or passive control systems can be installed in the building to reduce the wind response, although only an active control sample problem has been worked out to illustrate the control design. In the case of active control systems, either an active tuned mass damper or an active mass driver can be installed on the top floor. In the case of passive or semiactive systems, such as viscous dampers, viscoelastic dampers, electrorheological, or magnetorheological dampers, etc., c...