Quantitative analysis of changes in blood concentrations and 'presumed effect-site concentration' of sevoflurane during one-lung ventilation.
2012
Summary
During one-lung ventilation, ventilation-perfusion mismatch decreases the arterial concentration of inhaled anaesthetics due to the arterial-to-venous concentration difference. This study tested the hypothesis that in humans, the ‘presumed effect-site concentration’ (taken as the mid-point between the arterial and superior jugular venous concentrations) of inhaled anaesthetic falls during one-lung (vs two-lung) ventilation. Four patients scheduled for elective prostatectomy (two-lung ventilation) and four patients for elective thoracotomy (one-lung ventilation) were randomly selected and assigned to receive sevoflurane (vaporiser-dial setting, 1.5%). Sevoflurane concentrations were measured periodically from radial artery and superior jugular vein (via a catheter advanced cephalad from the jugular vein). During one-lung ventilation, the end-expiratory sevoflurane concentration was stable at ∼1.3% but the mean (SD) presumed effect-site concentration declined initially from 58 (6.7) to 43 (4.7) μg.ml−1 (p = 0.011) before slowly recovering. A period of insufficient depth of anaesthesia is thus a risk during one-lung ventilation.