Design of a synchronization system for the “Gamma-4” electrophysical facility

2014 
At RFNC-VNIIEF on the basis of a “Gamma-1” high-current pulsed accelerator there is being developed a four-module “Gamma-4” electrophysical facility. A synchronization system of the "Gamma-4" facility is meant for a simultaneous (with precision not worse than ±3 ns) triggering of high-volt gas-filled trigatron type switches of modules' pulse forming systems (144 items, operating voltage ≤ 1 MV), modules' pre-pulse switches (24 items, ≤ 3 MV) and 8 Marx generators (40 items, ≤ 100 kV). The synchronization system comprises 54 pulse generators, involving 25 generators on the basis of water insulated forming lines with distributed parameters and multi-channel gas-filled switches. On matched cable loads with resistances 0.45 Ohm these generators form voltage pulses with amplitudes 100 kV with durations 25 ns. A jitter of switches of these generators does not exceed ± 2 ns. To raise the amplitude of pulse drivers of pulse forming system switches and pre-pulse switches of modules in the facility synchronization ...