A rapid performance diagnosis of seawater reverse osmosis membranes: simulation approach

2010 
Recovery and salt rejection rate, which are directly related to the membrane properties and operating conditions (i.e., feed flow rate, pressure, temperature, and TDS concentration), are two main indicators for evaluating the performance of a reverse osmosis (RO) membrane process. A simple and rapid test with minimum data is inevitably requested to diagnose membrane performance at a certain operating conditions, because experiments at all operating conditions are inefficient and consumable work in the view of cost as well as man-hour. In this study, permeate flow rate and TDS concentration of three kinds of commercial RO membranes were carefully examined under various operating conditions [i.e., feed pressure (45–65 kgf/cm2) and temperature (5–30°C)]. Based on the experimental data, membrane resistance models including temperature and pressure correction factors were developed for the rapid diagnosis of SWRO membrane performances. As a result, the models developed in this study have good agreements betwee...