Strongly Temperature-Dependent, Anomalous Secondary Electron Emission of Liquid Lithium Surfaces Exposed to a Plasma

2021 
Abstract Electron-induced secondary electron emission (SEE) on a liquid lithium surface confined in a capillary porous system (CPS) and exposed to a plasma is reported for the first time. The liquid lithium surface is exposed to the bombardment of a suprathermal electron flux with energies up 150 eV created in a low pressure He Dc-Glow discharge. Various methods of surface oxidation have been used to reproduce realistic conditions in fusion plasma experiments. Exposure to very low residual gas pressures (around 3x10-7 Torr) is enough to increase the maximum of the SEE to values of about 2. The formation and dissolution of a surface oxide film is strongly temperature dependent and plays an important role in the resulting SEE yield and its time evolution: values have been found to range from ∼0.8 for clean surfaces to ∼2 for samples that have been heavily oxidized. In the case of O2 molecule exposure, a clear difference with temperature was observed. The molecular exposure at 330 °C had a much stronger effect on the increase in SEE than the molecular exposure at 220 °C. These results have a direct impact on the development of lithium-based divertor targets in fusion as well as in the understanding of the SEE characteristics of contaminated liquid surfaces, which has never been reported before.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    0
    Citations
    NaN
    KQI
    []