Speckle tracking global strain rate E/E' predicts LV filling pressure more accurately than traditional tissue Doppler E/E'.

2012 
Background: The ratio of early diastolic transmitral flow velocity (E) to tissue Doppler (TD) mitral annular early diastolic velocity (E/E′VEL-TD) has been widely used for the noninvasive assessment of LV diastolic filling pressures. However, it has been reported that E/E′VEL-TD is not accurate particularly when being applied to patients with advanced heart failure. Methods: Fifty-six ICU patients with decompensated heart failure underwent simultaneous echocardiography and PCWP measurements. Patients with elevated PCWP (n = 41) were compared with patients normal PCWP (n = 15) as well as age-matched healthy controls (n = 32). In the apical 4-chamber view, the ratio of E to speckle tracking (ST) mitral annular velocity (E/E′VEL-ST) and early diastolic global LV longitudinal strain rate (E/E′SR-ST) were evaluated as new surrogate markers of elevated PCWP. Results: Correlations with PCWP were observed for speckle tracking derived E/E′VEL-ST (r = 0.40,P = 0.002) and E/E′SR-ST (r = 0.56, P 12 (Sensitivity/Specificity/area under the ROC curve: 0.58/0.90/0.78), E/E′VEL-ST > 14 (0.60/0.85/0.80), and E/E′SR-ST > 93 (0.80/0.88/0.89). Conclusion: Speckle tracking derived E/E′SR-ST may be a robust surrogate marker of elevated LV filling pressure. In ICU patients, E/E′SR-ST showed better correlation with PCWP and higher diagnostic accuracy than the tissue Doppler approach. (Echocardiography 2012;29:404-410)