Evaluating the Accuracy of the VitalWellness Device

2019 
Background: Wellness devices for health tracking have gained popularity in recent years. Additionally, portable and readily accessible wellness devices have several advantages when compared to traditional medical devices found in clinical environments The VitalWellness device (VW) is a portable wellness device that can potentially aide vital sign measuring for those interested in tracking their health. Objective: In this diagnostic accuracy study, we evaluated the performance of the VW, a wireless, compact, non-invasive device that measures four vital signs (blood pressure (BP), heart rate (HR), respiratory rate (RR) and body temperature using the index finger and forehead. Methods: Volunteers age ≥18 years were enrolled to provide blood pressure (BP), heart rate (HR), respiratory rate (RR) and body temperature. We recruited participants with vital signs that fell within and outside of the normal physiological range.. A sub-group of eligible participants were asked to undergo an exercise test, aerobic step test and/or a paced breathing test to analyze the VW device’s performance on vital signs outside of the normal physiological ranges for HR and RR. Vital signs measurements were collected with the VW device and FDA-approved reference devices. Mean, standard deviation, mean difference, standard deviation of difference, standard error of mean difference and correlation coefficients were calculated for measurements collected; these measurements were plotted on a scatter plot and a Bland-Altman plot. Sensitivity analyses were performed to evaluate the performance of the VW device by gender, skin color, finger size and in the presence of artifacts. Results: 265 volunteers enrolled in the study and 2 withdrew before study completion. Majority of the volunteers were female (62%), predominately white (63%), graduated from college or post college (67%) and employed (59%). There was a moderately strong linear relationship between VW BP and reference BP, r = 0.7, P<0.05; and VW RR and reference RR measurements, r=0.7, P<0.05. The VW HR readings were significantly in line with the reference HR readings, r= 0.9, P<0.05. There was a weaker linear relationship between VW temperature and reference temperature, r = 0.3, P<0.05. There were no differences in performance of the VW device by gender, skin color or in the presence of artifacts. Finger size was associated with differential performance for RR. Conclusions: Overall, the VW device performed well in taking BP, HR and RR when compared to FDA-approved reference devices and has potential serve as a wellness device. To test adaptability and acceptability, future research may evaluate user’s interactions and experiences with the VW device at home. In addition, the next phase of the study will evaluate transmitting vital sign information from the VW device to an online secured database where information can be shared with HCPs within seconds of measurement.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []