Excitation Strategies for 3-D Electrical Capacitance Tomography Sensors

2021 
This article presents investigation of 3-D electrical capacitance tomography (ECT) sensors with different excitation strategies, including dual-electrode excitation in the same plane, in adjacent plane, in planes separated by one plane or two planes, and in the adjacent position or opposite position in the same or different planes. The results show that a 3-D ECT sensor with dual-electrode excitation in the opposite position provides higher mean capacitance and lower standard deviation than in the adjacent position. Dual-electrode excitation in different planes can increase the capacitance signal and decrease the dynamic range of capacitance measurements, and thus, decrease random errors and improve the quality of 3-D reconstructed images. A 3-D ECT sensor with dual-electrode excitation in planes separated by one plane and opposite position can provide small measurement uncertainty and high image quality.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    35