Research on accelerated storage life test for laser detectors

2020 
Based on the fact that laser detectors need to be stored for long time but used only once, the research on main stress and acceleration model, which affect storage life was performed. First, design principles for safe accelerated range of stress, stress forcing method and test time for accelerated test were presented, and the way to estimate the type of life distribution. Then, the method of accelerated model parameter evaluation based on maximum likelihood estimation (MLE) were proposed to calculate the accelerated factor. Finally, based on the accelerated factor, the test data was conversed for evaluation of storage life. The research of the paper can be used as a reference for products of the same type to evaluate the storage life.