Efek Penambahan APK Pipa Kapiler Bersirip Sebagai Penghantar Panas Terhadap Performance AC Pada Aplikasi ACWH

2021 
Technological advances encourage researchers to continue engineering technology. One of them is to increase the function of the A ir C onditioner (AC) from air conditioning to air conditioning and the provision of hot water for bathing needs ( A ir C onditioner W ater H eater / ACWH). This study aims to analyze the performance of the air conditioner due to the addition of a water heater application. The water capacity in the tank is 60 liters using a capillary tube heat exchanger with the addition of fins. The test was carried out at 3 different evaporator temperatures, namely 16 0 C, 18 0 C and 20 0 C. Data were collected for 60 minutes. The result is that the ACWH application is able to provide hot water for bathing needs, with a temperature of 55.5 0 C at the evaporator temperature test of 18 0 C. However, the addition of this application resulted in a decrease in AC performance (COP). The COP AC value obtained in the 20 0 C test was 3.071 while the ACWH application was 2.081.