Abstract Background Entrapment neuropathy of the radial nerve at the spiral groove region is relatively common. However, its localization may be technically challenging. Objective To evaluate the use of ultrasound (US), in relation to electrophysiological testing, for this purpose. Methods We studied 32 normal controls to obtain US parameters of the radial nerve. In addition, 10 patients with suspected radial neuropathy were tested using US and electrophysiological techniques. Results US examination correctly identified all 6 patients with radial neuropathy. The other 4 patients with alternate diagnoses did not show US abnormalities exceeding that of normal controls. US examination required a significantly shorter time than electrophysiological testing. Conclusions US is of value as a rapid diagnostic adjunct for the localization of radial nerve entrapment.