Hemodynamic outcome of different ventilation modes in laparoscopic surgery with exaggerated trendelenburg: a randomised controlled trial

2021 
Abstract Purpose To compare hemodynamic effects of two different modes of ventilation (volume-controlled and pressure-controlled volume guaranteed) in patients undergoing laparoscopic gynecology surgeries with exaggerated Trendelenburg position. Methods Thirty patients undergoing laparoscopic gynecology operations were ventilated using either volume-controlled (Group VC) or pressure-controlled volume guaranteed mode (Group PCVG) (n = 15 for both groups). Hemodynamic variables were measured using Pressure Recording Analytical Method by radial artery cannulation in addition to peak and mean airway pressures and expired tidal volume. Results The only remarkable finding was a more stable cardiac index in Group PCVG, where other hemodynamic parameters were similar. Expired tidal volume increased in Group VC while peak airway pressure was lower in Group PCVG. Conclusion PCV-VG causes less hemodynamic perturbations as measured by Pressure Recording Analytical Method (PRAM) and allows better intraoperative hemodynamic control in exaggerated Trendelenburg position in laparoscopic surgery.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    26
    References
    0
    Citations
    NaN
    KQI
    []