On site monitoring of smoking lounges in an office building based on the PM2.5 indicator

2006 
In this paper are summarized the final results of a two-month continuous monitoring campaign on seven smoking lounges and some copy areas in a building housing the offices of a big company. The monitoring is based in particular on the detection of suspended particulates, in order to confirm some experimental correlations of the PM10/ PM2.5 ratio in this critical situation. The experimental measures have been performed in smoking lounges equipped following the technical requirements of the Italian Regulation (DPCM 23 December 2003) recently approved (10 January 2005). The final results show how PM10 and PM2.5 concentrations in the proximity of smoking areas were similar to the conditions of an outdoor high-polluted environment while inside smoking lounges the mean values detected were respectively 110 and 60 µg/m 3 confirming the PM10/PM2.5 ratio of between 1.5