Characteristics of Welds of Pure Titanium Plate Using Ultrasonic Attenuation

2013 
This paper studies on mechanical properties, fractures, and ultrasonic characteristics of Pure Titanium welds using ultrasonic attenuation. Ti specimen was made by using AR purge gas. When the titanium weld specimen is fractured, Tensile tests were conducted in order to observe the ultrasonic signal changes. A scanning electron microscope(SEM) was used to observe changes in failure surface and an ultrasonic normal probe with the central frequency of 4 MHz was used to obtain ultrasonic signals. As a result, the value of the mechanical properties in the weld zone was lower than that in the base zone and heat affected zone(HAZ) from Ti. Also the grain size in the weld zone was bigger than that in the weld zone and HAZ from Ti. Ultrasonic signals using a RMS method presents correlation between envelope area and the tensile strength. Consequently, the ultrasonic method could be potential tool for integrity evaluation of the Ti weld zone.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    3
    References
    2
    Citations
    NaN
    KQI
    []