Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator

2013 
A pilot-scale, full lift, hypolimnetic aerator was used to examine the effect of diffuser pore diameter, depth of diffuser submergence, and gas flow rate on oxygen transfer, using four standard units of measure for quantifying oxygen transfer: (a) KLa20 (h−1), the oxygen transfer coefficient at 20 °C; (b) SOTR (g O2·h−1), the standard oxygen transfer rate; (c) SAE (g O2·kWh−1), the standard aeration efficiency and (d) SOTE (%), the standard oxygen transfer efficiency. Diffuser depth (1·5 and 2·9  m) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing in response to increased diffuser depth. Both KLa20 and SOTR responded positively to increased gas flow rates (10, 20, 30, and 40 L·min−1), whereas both SAE and SOTE responded negatively. Orifice diameter (140, 400, and 800  µm) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing with decreasing orifice size. These experiments demonstrate how competing design factors int...