ÜLKEMİZDEKİ ÇİFT DUVAR ARASI YALITIM UYGULAMALARINDA BETONARME KİRİŞLERİN OLUŞTURDUĞU ISI KÖPRÜLERİNİN DEĞERLENDİRİLMESİ

2005 
In this research, effects of the thermal bridges formed by beams and floors and cavity walls as applied form in Turkiye on the heat performance of the building are analyzed for terraced roof and normal story floors of the rein- forced concrete structure systems. Conditions with no insulation are also analyzed for comparison purposes. So, heat flow density and temperatures around the thermal bridges formed by beams and floors are calculated by Quick Field software, version 5.0 and obtained results have been evaluated. Results are similar for the terraced roof and normal story floors; however, enabling of the comfort conditions and energy efficiency are not possible if terraced roof floors are not insulated. Major problems appear in the joint section of the members at cavity walls.