Total and Viable Airborne Bacterial Load in Two Different Agricultural Environments Using Gas Chromatography-Tandem Mass Spectrometry and Culture: A Prototype Study

1998 
Airborne exposure to bacterial components found in agricultural environments can lead to pulmonary inflammation. Total (viable and nonviable) bacterial load was monitored in a stable and a dairy by a new approach, gas chromatography-tandem mass spectrometry measurement of muramic acid, a component of gram positive and gram negative bacterial peptidoglycan. Also used to assess the gram negative bacterial load were 3-hydroxy fatty acids, markers of bacterial lipopolysaccharide. Culture, an established procedure for assessing the viable bacterial portion of airborne dust, served as a basis for comparison. The muramic acid and 3-hydroxy fatty acid concentrations (total C12:0, C14:0, and C16:0) showed a correlation with an R2 of 0.81. Dust and muramic acid levels also correlated. However, although relative muramic acid levels were lower in the stable than the dairy, colony forming units (CFU) were considerably higher in the stable. The total bacterial load (estimated from muramic acid values) for both the stab...