Monitoring furosemide in racehorses participating in an EIPH program

1994 
Analytical procedures were developed to monitor furosemide concentrations in post-race serum and urine samples obtained from horses participating in an exercise-induced pulmonary haemorrhage (EIPH) program. High performance liquid chromatography with ultraviolet light detection proved a reliable, sensitive method for measuring urinary furosemide concentrations up to 12 h after administration of either 150 or 250 mg of the drug to race horses. However, this method was unreliable for determination of serum furosemide concentration. High performance liquid chromatography with fluorescence detection proved a reliable, sensitive method for measuring serum furosemide concentrations in horses administered 250 mg of the diuretic, permitting detection approximately 5–10 ng/ml 6 h after treatment. This method was applied field conditions where furosemide was administered to horses (between 150 and 250 mg intravenously) 4 h prior to the race. Analytical results assisted establishing a threshold concentration of 85 ng/ml for serum furosemide. was found that serum furosemide concentrations are a valid measure of compliance with furosemide administration in the EIPH program.