Local Stress Behavior of Post-Tensioned Prestressed Anchorage Zones in Continuous Rigid Frame Arch Railway Bridge

2018 
The concrete stress behavior and cause of cracking at the anchorage zones of top and bottom slabs of a post-tensioned prestressed concrete box beam were studied. Based on the complex stress distribution under local anchor problem for the Yichang Yangtze River Bridge, which is the longest continuous rigid frame arch railway bridge in the world, model tests were conducted. Two full-scale specimens of top and bottom slabs were fabricated and gradually loaded based on principle of equivalent stress. The goal was to analyze the longitudinal and transverse stress distributions of cross sections of specimens at various loading cases during the experiment. From the experimental results, it can be concluded that the mechanical behavior of the concrete and steel bars were in good agreement when prestressed tendons were loaded. Tensile stress of concrete in prestressed anchorage zone gradually increased and surpassed the ultimate tensile strength of concrete with the increasing load. Consequently, local longitudinal cracking was formed at the anchorage block. Some recommendations to avoid the concrete at the anchorage zone continuing to crack are summarized in this paper.