Failure of peripheral arterial balloon angioplasty: does platelet deposition play a role?

1991 
The pathophysiological response to peripheral percutaneous transluminal balloon angioplasty in 20 patients was investigated using 111-Indium labelled platelets. Platelet deposition was quantified by measuring the degree of radioactivity uptake at angioplasty and control sites using a computer linked system and expressing the uptake as a ratio of angioplasty/control. Following platelet labelling, scans were performed before angioplasty and at 1, 24 and 48h after angioplasty. To assess patency of the angioplasty, ankle brachial Doppler pressure indices were performed and supported by repeat angiograms if doubt of patency existed. All patients were followed-up at 1 week, 1 month and 6 months to correlate the degree of early platelet uptake with failure. The mean ± sem platelet radioactivity ratio at the angioplasty site increased from 1.1 ± 0.1 prior to the procedure to a peak of 2.1 ± 0.3 at 1 h ( p p p