Proposal for a 30-T pulsed magnet suitable for neutron scattering experiments

1995 
We describe a conceptual design for a 30-T vertical-field split-pair magnet suitable for neutron scattering studies. While the magnet is primarily intended for diffraction and spectroscopic studies using a pulsed neutron source, it might also have application for relaxational studies at steady-state sources. The magnet will have a 5-cm bore for sample environment equipment, a 1-cm gap for the neutrons to illuminate the sample and through which to observe the scattering. It will run with a repetition frequency of 2 Hz, and a pulse length of 3 ms. We discuss scientific and engineering considerations that led to this specification and describe the designs of both magnet and power supply.