Toward a sensible single antigen bead cut-off based on kidney graft survival

2018 
BACKGROUND: There is no consensus in the literature on the interpretation of single-antigen bead positive for a specific HLA antibody. METHODS: To inform the debate, we studied the relationship between various single-antigen bead positivity algorithms and the impact of resulting donor-specific HLA antibody (DSA) positivity on long-term kidney graft survival in 3237 deceased-donor transplants. RESULTS: First, we showed that the interassay variability can be greatly reduced when working with signal-to-background ratios instead of absolute median fluorescence intensities (MFIs). Next, we determined pretransplant DSA using various MFI cutoffs, signal-to-background ratios, and combinations thereof. The impact of the various cutoffs was studied by comparing the graft survival between the DSA-positive and DSA-negative groups. We did not observe a strong impact of various cutoff levels on 10-year graft survival. A stronger relationship between the cutoff level and 1-year graft survival for DSA-positive transplants was found when using signal-to-background ratios, most pronounced for the bead of the same HLA locus with lowest MFI taken as background. CONCLUSIONS: With respect to pretransplant risk stratification, we propose a signal-to-background ratio-6 (using the bead of the same HLA-locus with lowest MFI as background) cutoff of 15 combined with an MFI cutoff of 500, resulting in 8% and 21% lower 1- and 10-year graft survivals, respectively, for 8% DSA-positive transplants.