On CCFL at a PWR Hot-Leg Pipe Geometry and Comparison Between Results in COLLIDER 1/4th- and Kobe 1/15th-Scaled Facilities

2019 
AbstractCountercurrent flow limitation (CCFL) in a pressurized water reactor hot-leg pipe geometry with a 190-mm pipe diameter was investigated experimentally and numerically at the COLLIDER test facility of the Technical University Munich in the past 3 years. This paper summarizes the most important CCFL findings learned from the COLLIDER test facility and tries to explain the reasons for obtaining different descriptions, results, and conclusions at different CCFL experimental investigations. The factors that can affect CCFL experimental results are explained in detail including some scale effects. The necessary preconditions to compare two sets of data from different CCFL experimental investigations are discussed in detail. The difference among CCFL-related limits/curves is clarified taking data at the COLLIDER as an example. The limits included the limit of the transition from a supercritical into a subcritical flow (SSTL); the onset of CCFL limit (iCCFL) inside the hot-leg pipe; the onset of CCFL limi...