[Rapid determination of illicit beta2-agonist additives in health foods and traditional Chinese patent medicines with DCBI-MS/MS method].

2013 
A novel rapid method for detection of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines was developed with the desorption corona beam ionization mass spectrometry (DCBI-MS) technique. The DCBI conditions including temperature and sample volume were optimized according to the resulting mass spectra intensity. Matrix effect on 9 beta2-agonists additives was not significant in the proposed rapid determination procedure. All of the 9 target molecules were detected within 1 min. Quantification was achieved based on the typical fragment ion in MS2 spectra of each analyte. The method showed good linear coefficients in the range of 1-100 mg x L(-1) for all analytes. The relative deviation values were between 14.29% and 25.13%. Ten claimed antitussive and antiasthmatic health foods and traditional Chinese patent medicines from local pharmacies were analyzed. All of them were negative with the proposed DCBI-MS method. Without tedious sample pretreatments, the developed DCBI-MS is simple, rapid and sensitive for rapid qualification and semi-quantification of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines.