Severe Polyethylene Wear Requiring Revision Total Hip Arthroplasty in Three Dogs.
2016
Objective
To describe the occurrence of severe polyethylene wear of the acetabular component in 3 dogs that ultimately led to implant failure, and to report the outcome of revision of total hip arthroplasty (THA) in these cases.
Study Design
Case report
Animals
Dogs (n=3).
Results
Three dogs with hip dysplasia underwent routine THA before 2 years of age. All dogs became acutely lame 4–5 years after THA. Radiographs revealed acetabular cup wear in all cases, shell fragmentation in 2 cases, and additional stem failure in 1 case. All dogs underwent successful revision surgery, during which severe polyethylene wear and metallosis was observed. Revision surgery provided an excellent clinical outcome in all dogs from 10 months to 4 years post revision.
Conclusion
Polyethylene wear and implant failure may be a significant long-term complication of THA not previously recognized, which may be especially true when placed at an early age in a large breed, active dog, or in a dog with significant morbidity associated with other limbs. A successful revision was achieved in all 3 dogs. Additional investigation is warranted to document the risk factors associated with severe polyethylene wear in canine THA.