SAFE ENTRY OF THORACIC PEDICLE SCREWS: A MORPHOMETRIC ANALYSIS

2011 
The aim of the study was to assess the safety of a novel anatomical landmark in the placement of thoracic pedicle screws. It is our clinical observation that the sagittal plane of the screw trajectory is perpendicular to the plane of the superior articular facet, when the entry point is in the lateral half of the articular surface of the corresponding superior facet. Using SECTRA software on a PACS digital imaging system, morphometric analysis was performed on thoracic vertebrae imaged using computed tomography (CT). For inclusion, the scan had to have no reported bony abnormality. It was determined whether a trajectory as described at 90 degrees to the articular facet, with an entry point just caudal to the lateral half of the facet to a depth of 25mm would breach either the medial wall of the pedicle or lateral vertebral body wall anterior to the costovertebral facet. Sixty-two CT scans (744 segments, 1488 pedicle-facet complexes) were reviewed. 1154 complexes were suitable for full analysis. Exclusions were due to the lumbarisation of the T12 facet joints (62) or inability to clearly define the facet surface due to the plane of the CT slice (272). Of 1154 entry points assessed, 1154 (100%) were safe to be entered at 90 degrees to a depth of at least 25mm. We have demonstrated the safety and reliability of a novel anatomical landmark in normal thoracic pedicles. We believe this will improve sagittal plane alignment and reduce further the risk of medial pedicle breach.
    • Correction