Development of a Robust Ultrasonic-Based Sample Treatment To Unravel the Proteome of OCT-Embedded Solid Tumor Biopsies

2019 
An effective three-step proteomics workflow is proposed to overcome the pitfalls caused by polymers present in optimum cutting temperature (OCT)-embedded tissue during its preparation for mass spectrometry analysis. First, the OCT-embedded tissue biopsies are cleaned using ethanol and water in a sequential series of ultrasonic washes in an ultrasound bath (35 kHz ultrasonic frequency, 100% ultrasonic amplitude, 2 min of ultrasonic duty time). Second, a fast ultrasonic-assisted extraction of proteins is done using an ultrasonic probe (30 kHz ultrasonic frequency, 50% ultrasonic amplitude, 2 min of ultrasonic duty time, 1 mm diameter tip). Third, a rapid ultrasonic digestion of complex proteomes is performed using a microplate horn assembly device (20 kHz ultrasonic frequency, 25% ultrasonic amplitude, 4 min of ultrasonic duty time). As a proof of concept, the new workflow was applied to human normal and tumor kidney biopsies including chromophobe renal cell carcinomas (chRCCs) and renal oncocytomas (ROs). ...