Influence of Percutaneous Occlusion of Atrial Septal Defect on Left Atrial Function Evaluated Using 2D Speckle Tracking Echocardiography

2020 
Percutaneous occlusion of atrial septal defect (ASD) has recently become a standard therapeutic strategy, but little is known about left atrial (LA) function thereafter. The present study aimed to determine LA function in 43 children with ASD and 13 controls based on LA strain measured by two-dimensional echocardiographic speckle tracking (2DE-ST). Among these children, 12 underwent surgery (ASD-S), 31 had device closure (ASD-D), and 13 were included as controls. LA strain was significantly decreased after ASD-D but was not significantly altered after ASD-S, indicating that percutaneous occlusion of an ASD might decrease LA function. Furthermore, the size of the ASD device negatively correlated with LA strain. These results imply that ASD occlusion devices negatively influence LA function and might be important when decided therapeutic strategies for ASD. LA strain measured by 2DE-ST should become a good indicator of LA function after ASD treatment in children.