Risk factors for intraoperative lateral mass fracture of lateral mass screw fixation in the subaxial cervical spine

2014 
Object Although lateral mass screw fixation for the cervical spine is a safe technique, lateral mass fracture during screw fixation is occasionally encountered intraoperatively. This event is regarded as a minor complication; however, it poses difficulties in management that may affect fixation stability and clinical outcome. The purpose of this study is to determine the incidence and etiology of lateral mass fractures during cervical lateral mass screw fixation. Methods A retrospective clinical review of patient records was performed in 117 consecutive patients (mean age 57 years, range 15–86 years) who underwent lateral mass screw fixation using a modified Magerl method from 1997 to 2010 at a single institution. A total of 555 lateral masses were included in this study. The outer diameters of the screws were 3.5 or 4.0 mm. In the retrospective clinical analysis, the incidence of intraoperative lateral mass fractures was reviewed. Potential risk factors for this complication were assessed using multivari...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    30
    References
    11
    Citations
    NaN
    KQI
    []