Recurrent low output syndrome after the weaning from mechanical circulatory support for postcardiotomy cardiogenic shock

2002 
: We reviewed the cases of recurrent low output syndrome (LOS) after the weaning from mechanical circulatory support for postcardiotomy cardiogenic shock. Twelve patients were divide into 2 groups according to whether low output syndrome recurred or not, consisting of a recurrent low output syndrome (+) group [re-LOS (+) group, n = 6] and a recurrent low output syndrome (-) group [re-LOS (-) group, n = 6]. Between 2 groups, there was no statistical difference in preoperative left ventricular ejection fraction (LVEF), aortic closs-clamping time and cardiac index at the weaning from mechanical circulatory support. Only the LVEF at the weaning in the re-LOS (+) group was significantly less than that in the re-LOS (-) group (0.39 +/- 0.08 vs 0.62 +/- 0.19, p < 0.05). All patients in the re-LOS (-) group survived to discharge, while in the re-LOS (+) group, although 3 patients were re-supported by intra-aortic balloon pumping, 4 of 6 patients died of multiple organ failure and 2 survivors were in New York Heart Association class III. The results suggest that the key to survive to discharge after the weaning from mechanical circulatory support is whether the cardiac contraction could recover or not.