Measurement of Isokinetic Strength of Trunk Rotator Muscles by a Cybex Back Systems Torso Rotation Ttesting Rehabilitation Unit in Normal Subjects

1992 
The purpose of this article is to determine the strength of trunk rotator muscles at several isokinetic test speeds (60deg/sec, 120deg/sec, 154deg/sec) in normal subjects by using the Cybex TR unit (Back Systems Torso Rotation Rehabilitation Unit).Ninety-five subjects (56 males and 39 females) ranging in age from 14 to 71 years with a mean of 35.7 years were tested.There were many differences in peak torque and total work between males and females. Peak torque, total work and torque acceleration energy (TAE) in male subjects exceeded respective strengths for female subjects at all isokinetic speeds tested. Peak torque, total work and TAE gradually decreased in older subjects. Peak torque and total work decreased as isokinetic speed increased. Conversely TAE increased as isokinetic speed increased. There were no differences found between right and left rotator muscle strength.