Running and Transformation of Carbon Monoxide Purification Devices in Pressure Swing Adsorption with Water Coal Gas

2010 
Carbon monoxide purification process in pressure swing adsorption with water coal gas in YCCC is introduced in this paper.Causes of problems during running like adsorbent’s losing effects,liquid entrainment in feed gas,pipe blockage,exceeded vibration in the operation of vacuum pumps,etc are analyzed and the treatment measures to ensure safe,stable and long-time running of the system are stated in this paper.