Core loss evaluation of segment core in turbine generators by torque method

2007 
This paper presents core loss evaluation of a turbine generator model stator. The stator configuration does not make the magnetic flux distribution uniform, and the induction harmonics make the core loss calculation difficult. In this evaluation, the core losses are measured by rotating stator torque. As a result of the measurements, a half-lap-stacked stator obtains lower core losses and larger percentage of eddy current losses than a block-stacked stator. In addition, a gap between each segment makes in-plane eddy current loss increase. © 2006 Wiley Periodicals, Inc. Electr Eng Jpn, 158(2): 64–71, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/eej.20407
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    0
    Citations
    NaN
    KQI
    []