Polymeric (SU-8) Optical Microscanner Driven by Electrostatic Actuation

2009 
A torsional micromechanical scanner was fabricated using photosensitive polymer (SU-8). The scanner consists of two parts; top layer (micro mirror) and bottom layer (an anchor and electrodes). The SU-8 scanner is actuated by electrostatic force generated from the gap-closing electrodes. For the fabricated optical scanner with the mirror area of 3×3 mm 2 , the experimentally determined scanning angles were 0.85° and 3.1° for 60Hz (non-resonant) and 1.13 kHz (resonant) driving frequencies, respectively, at an input voltage of 160V. A polymer-based actuator offers advantages including a low-cost fabrication process and low frequency operation.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    13
    References
    8
    Citations
    NaN