Introducing gel dosimetry in a clinical environment: Customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy

2007 
Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction of geldosimetry in a clinical environment is described, including the whole chain of customizations and preparations required to introduce magnetic resonance (MR) based geldosimetry into clinical routine. In order to standardize geldosimetry in dose verifications for radiosurgery and intensity modulated radiotherapy(IMRT), we focused on both the customization of the gel composition and of the MR imaging parameters to increase its precision. The relative amount of the components of the normoxic, methacrylic acid based gel (MAGIC) was changed to obtain linear and steep dose response relationships. MR imaging parameters were customized for the different dose ranges used in order to lower the relative standard deviation of the measured transversal relaxation rate ( R 2 ) . An optimization parameter was introduced to quantify the change in the relative standard deviation of R 2 ( σ R 2 , rel ) taking the increase in MR time into account. A 9% methacrylic acidgel customized for radiosurgery was found to give a linear dose response up to 40 Gy with a slope of 0.94 Gy − 1 s − 1 , while a 6% methacrylic acidgel customized for IMRT had a linear range up to 3 Gy with a slope of 1.86 Gy − 1 s − 1 . With the help of an introduced optimization parameter, the mean σ R 2 , rel was improved by 13% for high doses and by 55% for low doses, without increasing MR time to unacceptable values. A mean dose resolution of less than 0.13 Gy has been achieved with the gel and imaging parameters customized for IMRT and a dose resolution from 0.97 Gy (at 5 Gy ) to 2.15 Gy (at 40 Gy ) for the radiosurgerydose range. The comparisons of calculated and measured relative 3D dose distributions performed for radiosurgery and IMRT showed an acceptable overall correlation. The gamma criterion for the radiosurgery verification with a voxel size of 1.5 × 1.5 × 1.5 mm 3 was passed by 96.8% of the voxels ( 1.5 mm distance, 8% in dose). For the IMRT verification using a voxel size of 1.25 × 1.25 × 5 mm 3 the gamma criterion was passed by 50.3% of the voxels ( 3 mm distance, 3% dose uncertainty). Using dedicated data analysis and visualization software, MR based normoxic geldosimetry was found to be a valuable tool for clinically based dose verification, provided that customized gel compositions and MR imaging parameters are used. While high dose precision was achieved, further work is required to achieve clinically acceptable dose accuracy.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    30
    References
    42
    Citations
    NaN
    KQI
    []