Identification of metabolites of honokiol in rat urine using 13C stable isotope labeling and liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry.

2013 
Abstract A general approach based on stable isotope labeling and UPLC/Q-TOF-MS analysis of in vivo novel metabolites of honokiol has been developed in our study. In this method, urine samples were collected after intravenous administration of mixture of regular and [ 13 C 6 ]-labeled honokiol at 1:1 ratio to healthy rats. The metabolites could be easily recognized by the determination of a chromatographically co-eluted pair of isotopomers (MS doublet peaks) with similar peak intensities and mass difference corresponding to that between isotope-labeled and non-isotope-labeled honokiol. A total of 51 metabolites were detected, 37 of which were tentatively identified based on mass accuracy (
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    22
    References
    21
    Citations
    NaN
    KQI
    []