The role of CT simulation in whole-brain irradiation

1999 
Abstract Purpose: Evidence is growing that incorrect field-shaping is a major cause of treatment failure in whole-brain irradiation (WBI). To evaluate the potential benefits of CT simulation in WBI we compared field-shaping based on 3D CT simulation to conventional 2D simulation. Methods: CT head scans were obtained from 20 patients. Conventional 2D planning was imitated by drawing the block contours on digitally reconstructed radiographs (DRR) by four radiotherapists. Critical parts of the target and the eye lenses were subsequently marked and planning was repeated using 3D information (“3D planning”). The results of both methods were compared by evaluation of the minimal distance from the field edge according to each site. Results: In conventional planning using DRR, major geographic mismatches ( Conclusions: CT simulation in WBI is significantly superior to conventional simulation with respect to complete coverage of the target volume and protection of the eye lenses. The narrow passage between the ocular lenses and lamina cribrosa represents a serious limitation. These patients are safely identified with CT simulation and can be referred for modified irradiation techniques.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    12
    Citations
    NaN
    KQI
    []